The HI5222K includes the HI5222 advanced research grade dual channel benchtop pH/ISE/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5222 is rich in features including 5 point calibration, selectable resolution, data logging, alarm limits, comprehensive GLP, and much more. It retains simplicity with both dedicated key for routine operation and virtual keys that guide the user through setup options. The HI5222 ensures confidence in measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.
The use of a magnetic stirrer allows for proper mixing and the sample to be homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time of a sensor in achieving a stable reading. The HI5222K pH meter (kit) includes the HI190M-1 compact magnetic mini-stirrer
The HI5222K includes two HI1131B glass body, double junction, refillable pH electrodes. The laboratory pH electrodes can be used with samples that range from pH 0-13 and at temperatures between 0 and 100 oC.
The HI5222K includes 500 mL bottle each of pH 4.01, 7.01, and 10.01 pH buffer. All pH calibration buffers are produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to +/- 0.01 pH @ 25°C and are traceable to NIST Standard Reference Materials (SRMs).
For maintenance the HI5222K is supplied with HI7060L general purpose cleaning solution and the HI70300L electrode storage solution . When the “clean electrode” message is displayed during the calibration of the HI5222 or there is a poor probe condition (i.e. less than 30%) then soak the pH electrode in the cleaning solution for 15 minutes to clean any deposits from the glass surface. After cleaning the probe should be rinsed with purified water and then allowed to soak in the storage solution for 2-3 hours. The electrode storage solution is also used when the electrode is not in use. Either place a small amount into the storage cap or into a beaker in order to maintain a properly hydrated electrode.
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
HI5222 is supplied with HI1131B pH electrode, HI7662-T temperature probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC adapter and instructions. |
|
115 VAC compact magnetic mini stirrer with Speedsafe™ technology with micro-stir bar (1) |
|
HI1131B double junction, glass body, refillable pH electrode |
|
pH 4.01 calibration buffer (500 mL) |
|
pH 7.01 calibration buffer (500 mL) |
|
pH 10.01 calibration buffer (500 mL) |
|
general purpose cleaning solution (500 ml) |
|
electrode storage solution (500 ml) |
pH Range | -2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH |
---|---|
pH Resolution | 0.1, 0.01, 0.001 pH |
pH Accuracy (@25ºC/77ºF) | ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD |
pH Calibration | automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers |
pH Temperature Compensation | automatic or manual from -20.0 to 120.0 °C |
mV Range | ±2000 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.2 mV ±1 LSD |
Relative mV Offset Range | ±2000 mV |
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K |
---|---|
Temperature Resolution | 0.1 °C, 0.1 °F, 0.1 K |
Temperature Accuracy | ±0.2 °C, ±0.4 °F, ±0.2 K |
ISE Range | 1 x 10⁻⁶ to 9.99 x 10¹⁰ concentration |
---|---|
ISE Resolution | 1; 0.1; 0.01; 0.001 concentration |
ISE Accuracy @ 25 °C/77 °F | ±0.5% (monovalent ions); ±1% (divalent ions) |
ISE Calibration Points | automatic, up to five point calibration, seven fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 choice of concentration) and five custom solutions |
Electrode/Probe | HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Probe | HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) | ||||||||||||||||
GLP | calibration data including date, time, buffers used, offset and slope | ||||||||||||||||
Logging | record: 100,000 data point storage, 100 lots with 50,000 records/lot; interval: settable between 1 second and 180 minutes max log time; type: automatic, manual, AutoHold | ||||||||||||||||
Input Channels | 2 - pH/ORP/ISE | ||||||||||||||||
Display | color graphic LCD with on-screen help, graphing, and custom color configuration | ||||||||||||||||
Connectivity | USB | ||||||||||||||||
Environment | 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing | ||||||||||||||||
Power Supply | 12 VDC adapter (included) | ||||||||||||||||
Dimensions | 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) | ||||||||||||||||
Weight | 1.2 kg (2.64 lbs.) | ||||||||||||||||
Ordering Information | The HI5222K dual channel pH/mV/ISE kit includes the following:
|
We train our customers on the operation and installation .. We also offer after-sales service to follow our customers constantly and always check on our devices and the speed of providing maintenance service when necessary